Displacement Sensors with External Thread

For rough environment M12 (M18) Housing – contactless, wear free, strokes 2, 5, 10, 20mm, individual designs – IP 65 (IP68)

LVDT-IMAL
LVDT-IMAT
LVDT-IGAL
LVDT-IGAT

Type
IMAL
IMAT
IGAL
IGAT

Stroke
2, 5, 10mm
2, 5, 10mm
2, 5, 10, 20mm
2, 5, 10, 20mm

Signal conditioning
external
external
external
external

Operation
unguided armature
spring return
unguided armature
spring return

Connection
plug or cable
plug or cable
plug or cable
plug or cable

Linearity tolerance
0.5% F.S.
(0.25% F.S optional)
0.5% F.S.
(0.25% F.S optional)
0.5% F.S.
(0.25% F.S optional)
0.5% F.S.
(0.25% F.S optional)

Rated temperature range
-25°C to +85°C
-25°C to +85°C
-25°C to +85°C
-25°C to +85°C

Protection degree
IP65 (optional IP67, IP68)
IP65 (optional IP67, IP68)
IP65 (optional IP67, IP68)
IP65 (optional IP67, IP68)

Options
see datasheet LVDT-IMAL
see datasheet LVDT-IMAT
see datasheet LVDT-IGAL
see datasheet LVDT-IGAT

Characteristics
M12 Housing, (steel zinc plated), contactless, wear free, individual designs
M12 Housing, (steel zinc plated), contactless, wear free, individual designs
M18 Housing, (steel zinc plated), contactless, wear free, individual designs
M18 Housing, (steel zinc plated), contactless, wear free, individual designs

Let's Talk!

Have a question? Need a quote? Contact us today!